BYHBD - INDIVIDUAL CHEMICAL AGENT DETECTOR, G ELECTROLYTE COMPONENT
- MSDS: BYHBD
- Manufacturer: ENVIRONMENTAL TECHNOLOGIES GROUP INC
- Product Name: INDIVIDUAL CHEMICAL AGENT DETECTOR, G ELECTROLYTE COMPONENT
- National Stock Number: 6665-01-340-1693
Product Identification
Product ID:INDIVIDUAL CHEMICAL AGENT DETECTOR, G ELECTROLYTE COMPONENT
MSDS Date:07/14/1993
FSC:6665
NIIN:01-340-1693
Kit Part:Y
MSDS Number: BYHBD
Responsible Party
BALTIMORE, MD 21284-9840
US
Emergency Phone: 410-321-5100 OR 410-321-5105
Info Phone: 410-321-5100 OR 410-321-5105
Cage: 23667
Contractor
Telephone: 301-321-5200
Cage: 23667
Ingredients
ETHYLENE GLYCOL (SARA 313) (CERCLA)
CAS: 107-21-1
RTECS: KW2975000
ACGIH TLV: C 50 PPM,VAPOR; 9495
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SODIUM TETRABORATE, ANHYDROUS (BORAX)
CAS: 1330-43-4
RTECS: VZ2275000
OSHA PEL 10 MG/M3
ACGIH TLV: 1 MG/M3; 9495
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ISONITROSOBENZOYL ACETONE
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 40 - 45%
Hazards
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:*RELEASE OF CHEMICALS, ICAD ACTIVATION
& SENSOR MODULE RUPTURE* ACUTE-EYE, SKIN ABSORPTION, INTOXICATION
EFFECT. CHRONIC-NOT APPLICABLE DUE TO VOLUME. *NORMAL ICAD
OPERATIONS* NO HEALTH EFFECTS, ACUT E OR CHRONIC.
Explanation of Carcinogenicity:MANUFACTURER GAVE NO INFORMATION ABOUT
CARCINOGENICITY. HMIS FOUND NO LISTING & DOES NOT EXPECT IT TO BE
CARCINOGENIC.
Effects of Overexposure:*RELEASE OF CHEMICALS, ICAD ACTIVATION & SENSOR
MODULE RUPTURE* INTOXICATION EFFECT, EYE & MUCOUS MEMBRANE
IRRITATION, BLURRED VISION. *NORMAL ICAD OPERATIONS* NO SYMPTOMS.
Medical Cond Aggravated by Exposure:*RELEASE OF CHEMICALS, ICAD
ACTIVATION & SENSOR MODULE RUPTURE* COPD (ASTHMA, EMPHYSEMA, TB,
BRONCHITIS). *NORMAL ICAD OPERATIONS* NONE.
First Aid
First Aid:EYE:WASH W/RUNNING WATER FOR MINIMUM OF 30 MIN. & SEEK
MEDICAL ATTENTION. SKIN:WASH W/RUNNING WATER FOR A MINIMUM OF 30
MIN. INHALATION:MOVE TO VENTILATED AREA (AWAY FROM SOURCE OF
EXPOSURE) - START O XYGEN THERAPY (IF NEEDED). INGESTION:DILUTE
W/LARGE QUANTITIES OF NEUTRALIZING SOLUTIONS (WATER, MILK).
Fire Fighting
Flash Point:>212F,>100C
Extinguishing Media:CARBON DIOXIDE, WATER, DRY CHEMICAL
Fire Fighting Procedures:MFR GAVE NO INFORMATION ON MSDS.
Unusual Fire/Explosion Hazard:MFR GAVE NO INFORMATION ON MSDS.
Accidental Release
Spill Release Procedures:MFR GAVE NO INFORMATION ON MSDS.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.
Handling
Handling and Storage Precautions:STORE MATERIALS IN TEMPERATE WAREHOUSE
ENVIRONMENT TO ENSURE PRODUCT INTEGRITY - NO POTENTIAL FOR OUTGAS
IF STORED UNDER TEMPERATE WAREHOUSE CONDITION
Other Precautions:INITIAL ACTIVATION OF ICAD SHOULD BE PERFORMED IN AN
OPENLY VENTILATED ENVIRONMENT TO ENSURE PERSONNEL SAFETY. (USE
I/A/W ICAD USER MANUAL.)
Exposure Controls
Respiratory Protection:NONE REQUIRED (USE I/A/W ICAD USER MANUAL.)
Ventilation:MFR GAVE NO INFORMATION ON MSDS.
Protective Gloves:NONE REQUIRED,USE I/A/W ICAD USER MANUAL
Eye Protection:NONE REQUIRED,USE I/A/W ICAD USER MANUAL
Other Protective Equipment:MFR GAVE NO INFORMATION ON MSDS.
Work Hygienic Practices:MFR GAVE NO INFORMATION ON MSDS.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:V5
NRC/State Lic Num:NONE
Boiling Pt:=108.9C, 228.F
B.P. Text:228F,109C
Vapor Density:2.1
Spec Gravity:1.12
Evaporation Rate & Reference:1.0 (CATBON TET = 1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS, SWEET TASTE, ODORLESS, HYGROSCOPIC
LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
MFR GAVE NO INFORMATION ON MSDS.
Stability Condition to Avoid:STRONG OXIDIZING & REDUCING AGENTS
Hazardous Decomposition Products:MFR GAVE NO INFORMATION ON MSDS.
Conditions to Avoid Polymerization:MFR GAVE NO INFORMATION ON MSDS.
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS. (REFER TO 40CFR FOR GUIDANCE.)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.